CONTACT

Redefining point-of-care diagnostics

  • Easy-to-use analysis in the field or patient-side1
  • Diagnostic insights in 2-3 minutes for most test runs1
  • Minimal maintenance and no calibration required for maximum efficiency1
  • Blood gas and acid-base analysis on a cartridge-based handheld
  • Comprehensive internal quality control measures1
  • Intuitive touch screen and on-screen assistance1

Expand your practice with anytime portable diagnostics

medical-icon medical-icon medical-icon

Efficient, reliable data

Easily capture a variety of actionable diagnostic results with automated quality control checks during every sample run for optimal performance and reliability.

management-icon management-icon management-icon

Streamlined workflow

Maximize efficiency at critical moments in patient care with easy-to-operate technology that requires minimal maintenance and provides results in just 2-3 minutes.

money money money

Advanced patient care

Optimize your practice with multiple STAT testing capabilities on a compact, easily-portable analyzer, so you can provide continuous care with fewer delays to more patients.

How it works

  • Rely on quality data at critical moments in the field or clinic
  • Access results across a range of analytes, including acid-base, lactate, ionized calcium, blood gas, electrolytes and measured hematocrit
  • Review rapid results easily in real time
  • Share results with multiple connectivity solutions that fit your clinic’s needs
  • Dimensions:
    10.10 x 5.60 x 3.20 in, 25.65 x 14.22 x 8.13 cm (HxWxD)
  • Operating Temperature:
    61°-86°F, 16°-30°C for i-STAT cartridge testing
  • Relative humidity:
    10-90%, non-condensing, with maximum saturation temperature of 122ºF, 50°C
  • Power:
    Lithium Ion Rechargeable Battery, 3.65 (nominal) VDC, 19.3 Wh
  • Weight:
    1.5 lbs, 0.68 kg without battery, 1.9 lbs, 0.86 kg with battery
  • Storage Temperature:
    14°-140°F, -10°-60°C
  • Altitude:
    Up to 10,000 feet
  • Display:
    5 in, 12.7 cm; 800 x 480 pixels with touchscreen, measured diagonally

Frequently Asked Questions

The i-STAT system consists of 3 components: the Alinity v handheld analyzer, a single-use biosensor cartridge, and information software interface. The technology combines silicon chip manufacturing with classic electrochemistry, facilitating the rapid reporting of laboratory parameters.

The i-STAT Alinity v offers a variety of disposable, single-use cartridges that include analyte combinations for acid-base analysis, blood gases, chemistry, hematology, electrolytes, and some specialty tests like lactate. These cartridges are configured with parameters that can give insight into a patient's condition depending on the clinical situation.

Whole blood samples only (venous or arterial) without anticoagulant, or whole blood collected into lithium heparin tubes may be used.

The cartridges are manufactured with 5-11 months shelf life, and shelf life will differ with each cartridge. Refer to the expiration date on the product box for shelf life.

To maximize shelf life, store all i-STAT test cartridges in the refrigerator at 35°-46°F. Once removed from the refrigerator, cartridges can be stored at room temperature (64°-86 °F) for up to 2 weeks – refer to cartridge box for additional information. Once a cartridge has been warmed to room temperature, do not return it to the refrigerator.

Canine, feline, and equine.

Measured: hematocrit (Hct), blood urea nitrogen (BUN), creatinine (Crea), ionized calcium (iCa), glucose (Glu), chloride (Cl), sodium (Na), potassium (K), pH, partial pressure of carbon dioxide (pCO2), partial pressure of oxygen (pO2), and lactate.

Calculated: hemoglobin (Hb), bicarbonate (HCO3), total carbon dioxide (tCO2)*, oxygen saturation (sO2), anion gap (AnGap), and base excess (BE).

*tCO2 is a measured analyte on the CHEM8+ cartridge and a calculated value on the CG4+ and CG8+ cartridges

No. Before running a test, each cartridge initiates a series of pre‑set internal quality control diagnostics, from monitoring the quality of the sample to validating the reagent.

If stored in the refrigerator, allow to warm to room temperature before running a test or adding sample. This is typically ~5 minutes for one cartridge and up to 60 minutes for a box of cartridges.

New software incorporates refinements to the internal quality monitoring system and allows the i-STAT Alinity v to recognize any newly launched cartridge types and to perform any newly launched features.

The only maintenance required for the i-STAT Alinity v is a software update twice a year.

17-95 µL, depending on the cartridge used.

The operating temperature for i-STAT cartridge testing is 61°-86°F. If it is out of this range, please take proper steps to get the analyzer back into this temperature before running a test.

Note: The i-STAT Alinity v analyzer will display an alert if the analyzer is outside of operating temperature.

Downloadable Resources

Looking for more information? Find what you need in our Resource Center.

poweredby-virtual-lab poweredby-virtual-lab poweredby-virtual-lab

Bringing specialist-level medicine to your clinic

The Zoetis Virtual Laboratory offers deeper insights through its unique portfolio of interconnected diagnostic products and services. Connecting in-clinic diagnostic testing with expert support, the Virtual Laboratory empowers confident treatment decisions and elevates patient care.

  • Best-in-class AI
  • Anytime* expert support
  • Connected diagnostic insights

Discover the difference Zoetis Handheld Analyzers can make in your clinic

Contact us today to learn more about how our diagnostics portfolio can help you provide elevated patient care.

Customer Service, Support & Ordering

Mon – Fri: 8:30am – 6:30pm ET

Vetscan & i-STAT Technical Support

24 hours a day, 7 days a week, 365 days a year

1-888-963-8471

Zoetis Reference Laboratories Customer Service, Support & Ordering

Mon – Fri: 8:00am – 9:30pm ET

Saturday: 9:00am – 8:30pm ET

Sunday: Closed

1-888-965-9652

Need Technical Support?

Our support team is available to answer product questions and provide guidance.

* Dependent on consultant availability.

If you are a pet owner looking for treatment recommendations, please contact your veterinarian.

Reference: 1. Data on file. LBL-03069, Zoetis Inc.

Request support

Request Support

Use this form to make product inquiries, report a product related event, or raise a product quality issue, and a Zoetis Representative will be in touch.

Thank you for your submission!

Your Zoetis representative will reach out to you soon.

close

Sorry, form submission has failed. Please try again.

close

All fields are required.

Remove

This field is required Please enter a valid postcodePlease add your zip details by using search for your clinic

This field is required

This field is required

This field is required Please enter a valid e-mail address

This field is required Please enter a valid phone number

Please select at least one testing application

This field is required

Please accept the terms of use and privacy policy to continue

Request a demonstration

Request More Information

Ready to see our diagnostic portfolio in action? Simply complete the form below and a Zoetis representative will be in touch to answer your questions, provide more information or schedule your complimentary demonstration.

Thank you for your submission!

Your Zoetis representative will reach out to you soon.

close

Sorry, form submission has failed. Please try again.

close

Request more information

Request More Information

Interested in hearing more about the new technology partnership with Covetrus Pulse™? Simply complete the form below to learn more or schedule an installation with a Zoetis Representative.

Thank you for your submission!

Your Zoetis representative will reach out to you soon.

close

Sorry, form submission has failed. Please try again.

close

Request an Integration

Request an Integration

Use this form to request a bidirectional integration and a Zoetis representative will be in touch.

All fields are required.

Thank you for your submission!

Your Zoetis representative will reach out to you soon.

close

Sorry, form submission has failed. Please try again.

close

Request a Confirmatory Test
clinic info
Request Support Form